![]() Object is of type and, its state is online, but not all children are online. The type of object cannot be or and at the same time. These attributes are incompatible only one of them may be used. The node has both attributes "LieOffline" and "ClusterExclusive" set. Node has no detector while all its children's "MonitorOnly" attributes are set to 1. Increase the ScriptTimeout value for objectname (currently value seconds) to be greater than the detector cycle time (currently value seconds). This will cause a script timeout error to be reported before the detector can report the state of the resource. The node has a ScriptTimeout value that is less than its detector report time. Nodes of type gResource must have a valid rKind attribute. The NoKindSpecifiedForGdet is, so no kind specified in hvgdstartup. The DuplicateLineInHvgdstartup is, so the hvgdstartup file has a duplicate line. The rName is, its length length is larger than max length maxlength. This node uses a detector and therefore it needs a valid DeviceName attribute. The node has an empty DeviceName attribute. The node is a leaf node and this type does not have a detector. Nodes must be children of one and only one userApplication node. The node belongs to more than one userApplication, app1 and app2. Only the direct descendants of userApplication can have the HostName attribute set. Object cannot have its HostName attribute set since it is not a child of any userApplication. The message can be any one of the following: If some of these sanity checks fail, then this message will be printed and dynamic modification is aborted.Ī FATAL message is also printed to the switchlog with more details as to why the sanity check failed. No objects are and and or at the same time.ĬlusterExclusive and LieOffline, which are mutually exclusive, are not used together. The ScriptTimeout value is greater than the detector cycle time. The kind argument for the detector in the hvgdstartup is specified.Ī valid value has been specified for the rKind attribute. There are no duplicate lines in the hvgdstartup file. The length of the attribute rName for the leaf objects is smaller than the maximum. Leaf objects that have the DeviceName attribute have it set to a valid value. ![]() The child of a userApplication does not have another parent.Įach object belongs to only one userApplication. The HostName attribute is present only for children of userApplication objects. " 6.1.3.15 SWT: Switch requests (hvswitch command)"ĭynamic modification performs some sanity checks to ensure that all of the following are true: " 6.1.3.8 CUP: userApplication contracts" " 6.1.3.6 CRT: Contracts and contract jobs" " 6.1.3.3 BAS: Startup and configuration error" " 6.1.3.2 ADM: Admin, command, and detector queues" The component names are explained in numerical order of messages. This chapter contains a detailed list of non-fatal RMS error messages output in the switchlog file.Ĭheck displayed component names of messages and then see the table below to determine references.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |